High-Voltage Corona Discharge Hardware Tampa Electronics Test Bay // 10,000 mg/h Unoccupied Shock Treatment Only

High-output corona discharge ozone generators eradicate airborne contaminants at molecular scale.

Aromatek supplies commercial-grade corona discharge ozone generators ($59–$95 USD) for short-term rental turnovers, property restoration teams, and automotive detailers. Operating via high-voltage ceramic mesh plates, each device generates active triatomic oxygen (O3) to oxidize airborne thiols, stale tobacco smoke, and severe biological residue in unoccupied enclosures.

Generation Tech: High-Frequency Corona Discharge Confirmed Pricing: 59–95 USD per unit Ozone Yield: 5,000 to 10,000 mg/h Timer Mechanism: 120-Minute Mechanical Countdown Lead Time: 1–3 Days from Tampa Depot

We do not mask burnt grease or damp mildew with artificial perfume; when organic odor molecules bond into porous drywall and vehicle headliners, active ozone chemically cleaves their molecular bonds. Ozone treatment requires an empty room. Turn the timer to 60 minutes, lock the perimeter, and let the ceramic discharge plates neutralize the odor core.

Confirmed Pricing Schedule & Model Tiers

Tampa Depot Direct

Confirmed unit pricing runs strictly from 59 to 95 USD per unit. What your final order quote depends on is room volume capacity (compact 5,000 mg/h unit vs. heavy commercial 10,000 mg/h chassis), replacement ceramic plate bundles, and whether you order individual remediation units or multi-chassis facility sets.

Model OZ-500 (5,000 mg/h) 59 USD / unit
Model OZ-1000 Heavy Commercial (10,000 mg/h) 95 USD / unit
Commercial ozone generator device with steel carry handle and mechanical timer dial.

Commercial ozone generator in powder-coated steel chassis. Features a stainless steel folding handle, intake air filter, and analog mechanical 120-minute countdown dial.

Bench Inspection Tampa // Model OZ-1000

Molecular oxidation mechanism: how triatomic oxygen destroys thiol bonds.

Standard odor sprays wrap foul odors in volatile synthetic esters, temporarily deadening human olfactory receptors while the underlying contaminant festers. When treating severe property damage, burnt organic matter, animal waste, or deep cigarette smoke, the contaminant resides inside porous plaster, carpet underlayment, and fiberglass insulation.

Aromatek ozone generators convert atmospheric oxygen (O2) into unstable triatomic ozone (O3) by passing ambient air across high-voltage corona discharge ceramic plates. The extra oxygen atom has a high oxidation potential (2.07 volts). As O3 circulates through an enclosed space, it collides with airborne sulfur compounds, volatile fatty acids, and bacteria cell membranes. The third oxygen atom breaks free, violently oxidizing the target molecule into odorless carbon dioxide and water vapor, while reverting the remaining molecule to pure oxygen (O2). Half-life in ambient Florida conditions is approximately twenty to thirty minutes.

Mandatory Operational Safety Directive

TREATMENT REQUIRES UNOCCUPIED SPACES ONLY: High concentrations of ozone gas are hazardous to humans, pets, and live plants. Never operate an Aromatek ozone generator in an occupied room. Set the mechanical countdown timer, post warning signs on all perimeter doors, vacate the premises, and do not re-enter until at least 45 minutes after the machine’s timer has expired to allow O3 to revert to O2.

Operational Parameter Studio Model OZ-500 ($59) Commercial Model OZ-1000 ($95)
Ozone Gas Yield 5,000 mg/h (5 grams per hour) 10,000 mg/h (10 grams per hour)
Target Volume Coverage Up to 1,000 sq ft (cabin / studio) Up to 3,500 sq ft (residential / commercial)
Discharge Plate Grid Single 90×50mm Ceramic Mesh Plate Dual High-Frequency Ceramic Plates
Air Volume Flowrate 80 CFM Ball-Bearing Axial Fan 140 CFM High-Static Axial Fan
Chassis Housing 1.0mm Powder-Coated Steel Chassis 1.2mm Reinforced Steel with Stainless Grille
Timer Control Mechanical 120-Min Dial + Hold Mode Mechanical 120-Min Dial + Hold Mode
Electrical Specification 110V / 60Hz AC, 55 Watts Draw 110V / 60Hz AC, 95 Watts Draw

Verified Tampa operations and commercial hardware support.

Aromatek calibrates, electrical tests, and dispatches every ozone purifier from our workshop at 42 Aegean Avenue, Tampa, Florida 33606. Operating since 2026, we maintain active commercial registration in Tampa, issue formal purchase order documentation with verifiable tax records, and hold membership in the regional trade association.

Unlike unbranded drop-shipped machines with fragile plastic transformers, Aromatek units feature potted copper-wound high-voltage transformers and heavy steel housings that withstand the daily abuse of job sites and rental turnover vans. We stock hundreds of replacement ceramic discharge plates and air filter screens in our Tampa depot, shipping all replacement parts within 1 to 3 business days.

Transformer Life > 5,000 Hours

Epoxy-potted internal windings isolate electronics from atmospheric moisture.

Plate Service Interval 12–18 Months

Quick-release ceramic plates can be washed in isopropyl alcohol or replaced in 2 minutes.

Fulfillment Window 1–3 Business Days

Packed in double-wall unbleached cartons with molded pulp corner protectors.

Step-by-step room remediation protocol.

Follow this four-step procedure when performing odor shock treatments in residential rooms, hotel suites, or automotive interiors:

  1. Physical Source Removal: Mechanically remove the original odor source (empty ashtrays, clean spoiled food, vacuum pet fur, or wash stained fabrics). Ozone treats airborne and surface molecules; it cannot dissolve a physical pile of garbage.
  2. Space Clearance & Perimeter Lock: Remove all people, pets, and live house plants from the treatment area. Close all exterior windows and HVAC return dampers.
  3. Timer Setting & Activation: Place the generator on a raised surface (such as a table or center console). Rotate the mechanical dial to the calculated runtime (typically 30 minutes for cars, 60 minutes for hotel rooms, 120 minutes for smoke-damaged homes). Immediately exit and lock the door.
  4. Post-Treatment Ventilation: After the machine turns off automatically, wait an additional 45 minutes for residual ozone to decay back into stable oxygen. Open windows for 10 minutes to restore fresh outdoor air circulation.

When not to use corona ozone machines.

Do not purchase an ozone generator if you are seeking a 24/7 continuous air purifier to sit next to your bed while you sleep. Ozone is a harsh industrial oxidizing gas; breathing it causes airway irritation and coughing. For ongoing occupied spaces, deploy our passive Capillary Reed Diffusers ($39–$68) or spray localized target zones with our Bio-Enzymatic Room Sprays ($17–$19). Use ozone strictly as an episodic shock remediation tool for vacant rooms between tenant occupancies or detail turnarounds.

Learn more about industrial odor chemistry in our technical guide to Commercial Odor Elimination & VOC Remediation, or inspect our full equipment range in the Catalog Master Index.

Submit an Ozone Equipment or Fleet Procurement Inquiry

Select your model tier, target remediation volume, and facility location. Our technical fulfillment desk returns confirmed quotes and dispatch dates within one business day.

Please enter your full name or company representative name.
Please provide a valid email address.
Please provide a valid telephone number.